Split Core (Tilt Top) Miniature Current Transformers
Miniature Split (Windows under 1/2"), Accuracy Class 0.5, 1.0 250V/600V
-
UL 2808 Listed E361441
-
Input 5A to 100A
-
Output 333mV, 250mV etc.
-
Accuracy Class 0.5
-
Window 0.35”
-
UL Recognized E318465
-
Input 5A to 100A
-
Output 333mV, 250mV etc.
-
Accuracy Class 0.5
-
Window 0.45”
-
UL Recognized E318465
-
Input 5A to 100A
-
Output 333mV, 250mV etc.
-
Accuracy Class 0.5
-
Window 0.35”
Small Split Core (Windows up to 1.5"), Accuracy Class 0.5, 0.2 600VAC
Split Core (Removable Top) Current Transformers
-
UL 2808 Listed E361441
-
Input 10A to 800A
-
Output 333mV, 250mV etc.
-
Accuracy Class 0.2/0.5/1.0
-
Window 0.5” to 1.5”
-
UL 2808 Listed E361441
-
Input 10A to 800A
-
Output 333mV, 250mV etc.
-
Accuracy Class 0.2/0.5/1.0
-
Window 0.5” to 1.5”
-
Rust Proof Nickel Core
-
Input up to 300A
-
Output 333mV, 250mV etc.
-
Accuracy Class 0.2/0.5/1.0
-
Window 0.75”
Split Core (Tilt Top) Current Transformers
Small Split Core (Windows up to 2"), Accuracy Class 1.0, 0.5, 0.2
-
UL 2808 Listed E361441
-
Input 50A to 800A
-
Output 5VAC, 333mA, 333mV etc.
-
Accuracy Class 0.5/1.0
-
Widow 1.25"
-
UL 2808 Listed E361441
-
Input 10A to 150A
-
Output 333mV, 250mV etc.
-
Accuracy Class 0.5/1.0
-
Widow 1.0”
-
UL 2808 Listed E361441
-
Input 10A to 300A
-
Output 333mV, 250mV etc.
-
Accuracy Class 0.5/1.0
-
Widow 1.0”
Split Core (Tilt Top or Removable) Current Transformers
Small Split Core (Windows up to 1.25"), Revenue Grade, Accuracy Class 0.2s
-
UL 2808 Listed E361441
-
Input 1A to 100A
-
Output 333mV, 250mV etc.
-
Accuracy Class 0.5
-
Window 0.47”
-
UL 2808 Listed E361441
-
Input 1A to 100A
-
Output 333mV, 1VAC etc.
-
Accuracy Class 0.5
-
Widow 0.4”
-
UL 2808 Listed E361441
-
Input 15A to 200A
-
Output 333mV, 1VAC etc.
-
Accuracy Class 0.5
-
Widow 0.7”
-
UL 2808 Listed E361441
-
Input 50A to 600A
-
Output 333mV, 1VAC etc.
-
Accuracy Class 0.5
-
Window 1.25”
Sentran Corporation offers “private labeling” for these products — this means we manufacture your branded transformer products with your label. Give us a call and we’ll get you started.
Split Core (Removable or Tilt Top) Current Transformers
Outdoor, Submersible, Waterproof, Accuracy Class 0.6, 0.5, 0.3
-
UL 2808 Listed E361441
-
Input 50A to 800A
-
Output 5VAC, 333mA, 333mV etc.
-
Accuracy Class 0.5/1.0
-
Window 1.25"
-
Weather Proof IP68
-
Input 50A to 5000A
-
Output 1A or 5A
-
Accuracy Class 0.5/1.0
-
Multiple Sizes, Vary depending on VA/Burden
Split Core (Removable Top) Current Transformers
Small Split Core (Windows up to 2" and larger ), 333mV or 5A Output, Accuracy Class 1.0, 0.6, 0.5, 0.3
-
UL Recognized E318465
-
Input 50A to 6000A
-
Output 5VAC, 333mA, 333mV etc.
-
Accuracy Class 0.5/1.0
-
12 Standard Window Sizes
-
UL 2808 Listed E361441
-
Input 50A to 6000A
-
Output 5VAC, 333mA, 333mV etc.
-
Accuracy Class 0.5/1.0
-
12 Standard Window Sizes
-
UL 2808 Listed E361441
-
Input 100A to 8000A
-
Output 1A or 5A
-
Accuracy Class 0.3/0.5/1.0
-
Window 1.25x2.0" to 6"x8"
-
Custom Sizes
Split Core (Removable Top Cover) Current Transformers
Medium Voltage to 4160VAC
-
Input 100A to 8000A
-
Output 1A or 5A
-
Accuracy Class 0.5/1.0
-
Window Standard / Custom
-
Input 100A to 4000A
-
Output mV or mA Outputs
-
Accuracy Class 0.5/1.0
-
Window Sizes from 2"x2" to 8"x8"
-
Input 10A to 1500A
-
Output 0-20mADC or 4-20mADC
-
Accuracy Class 0.5/1.0
-
Window Sizes from 0.5" to 4.0"
-
Input 100A to 10,000A
-
Output 2.5VDC up to 10VDC
-
Accuracy Class 0.5/1.0
-
Window Standard / Custom
-
No power supply required
Don't forget the Mount. Sentran offers multiple options. Let us help!
Split Core (Removable or Tilt Top) Current Transformers
Relay Protection, C10 to C800, 5P10, 5P20
-
Input 600A to 6000A
-
Output 5A
-
5P10 & 5P20 Series
-
Window Standard / Custom
-
Rugged Polycarbonate Housing
-
Input 100A to 3000A
-
Output 5A
-
Relay Class / C10 to C400
-
Window Size 2.5"x6.5" & 4.0"x11"
-
Grain oriented magnetic steel