Model SRT | Rogowski Coils and Amplifiers

MTX | Current Transformer Mounts

Model 4TRMS | True RMS Split Current Transformer

Model 5AUXS | Auxiliary Current Transformer

Model VT3 | 3 Phase Voltage Monitor

Model 3AS | Harvest Split Current Transformers and Harvesting Systems

Model 2VN & 2AN | Voltage or Low Current Output Nickel Toroid

Models: Model 2VN and 2AN Class 0.2 or Class 0.1 Accuracy

Description

The Model 2AN and 2VN are indoor type toroidal current transformers for Measurement Category Class III as an accessory for UL Listed energy monitoring equipment to meet the requirements of UL2808 and CSA 61010-1 2nd Edition. All units can be potted using UL recognized potting compound for outdoor use. The case is high temperature UL recognized plastic. The 2VN is provided with an external burden resistor for calibrated output voltage. The 2AN is a ratio type for 0.1A output current for use with an external burden resistor. The current transformers are provided with up to 8′ black/white twisted MTW 18AWG UL1015 leads rated to 600VAC.

Specifications

 

  • 2AN(current out), 2VN (volts out)
  • +/- 0.2% Accuracy (Class 0.2 or Class 0.1 Optional)
  • Low Phase Shift
  • Current Ranges 10A to 400A
  • Output Voltages 100mV to 1000mV
  • Output Current of 0.1A (optional)
  • Window Sizes up to 1.5″ ID
  • UL Listed to UL2808, XOBA>

 

Downloads
http://www.sentrancorp.com/wp-content/uploads/2017/06/2AN-2VN.pdf

Model 2AS, 2VS, 2AN, 2VN | Toroidal Round Current Transformers

Models: 2AS, 2VS, 2AN, 2VN Class 1.0, Class 0.5, Class 0.2, Class 0.1

Description

Toroidal (Round) Toroidal style Current Transformers are available from Sentran Corporation for Class 1.0, 0.5, 0.2 and 0.1 per IEC61869 Tables 201 and 202. A special magnetic alloy is used. The Model 2AS and 2VS are indoor type toroidal current transformers for Measurement Category Class IV as an accessory for UL listed energy monitoring equipment to meet the requirements of UL2808 XOBA. All units can be potted using UL recognized potting compound for outdoor use. The case is high temperature UL recognized plastic or epoxy molded housing (not shown). The 2VS is provided with an internal burden resistor for a calibrated output voltage. The 2AS is a ratio type 0.1A output current for use with an external burden resistor. The current transformers are provided with up to 8′ black/white twisted MTW 18AWG UL1015 leads rated to 600VAC.

Specifications

 

  • 2AS (current out), 2VS (volts out), Class 1 and 0.5
  • 2AN (current out), 2VN (volts out), Class 0.2 and 0.1
  • Accuracy +/- 1.0% or +/- 0.5%
  • UL Listed to U2808, XOBA
  • Phase shift per 60o44-1 Table 11
  • Current Ranges 10A to 400A
  • Output Voltages 100mV to 1000mV
  • Output Current of 0.1A (optional)
  • Window Sizes from 0.5″ to 3.5″ ID

 

Downloads
http://www.sentrancorp.com/wp-content/uploads/2017/08/2AS-to-2AN-Combined.pdf

Model 2VS | Voltage Output Iron Toroid

Models: 2AS | 2AN | 2VN | 2VS | 2GN | 2VS Add more info

Description

The Model 2AS and 2Vs are indoor type toroidal current transformers for Measurement Category Class IV as an accessory for UL listed energy monitoring equipment to meet the requirements of UL2808 XOBA. All units can be potted using UL recognized potting compound for outdoor use. The case is high-temperature UL recognized plastic or epoxy molded housing (not shown). The 2VS is provided with an internal burden resistor for a calibrated output voltage. The 2AS is a ratio type 0.1A output current for use with an external burden resistor. The current transformers are provided with up to 8′ black/white twisted MTW 18AWG UL1015 leads rated to 600VAC.

Specifications

 

  • 2AS (current out), 2VS (volts out).
  • Accuracy +/- 1.0% or +/- 0.5%
  • UL Listed to U2808, XOBA
  • Phase shift per 60o44-1 Table 11
  • Current Ranges 10A to 400A
  • Output Voltages 100mV to 1000mV
  • Output Current of 0.1A (optional)
  • Window Sizes from 0.5″ to 3.5″ ID

 

Downloads

Model 4AN4 | Nickel Split Current Transformer | Revenue Grade

Copyright © 2017 Sentran Corp. All rights reserved.